OiD20Ah-50.4 50.4V 20Ah Lithium Ion Battery Pack 50A 300Cycle
Product Name
Lithium-Ion Battery Pack (Li-ion)
Advantages
Specifications
Parameter | Value | Unit | Comments |
Nominal Voltage | 50.4V | DC | Non-parallel/series connection allowed. |
Rated Capacity | 20Ah | @0.5C | Based on 14S4P cell configuration (IFR32700-5A 3C). |
Max Charge Current | 10A (25°C±2) | @Constant Current (CC) | Up to 58.8V (constant voltage phase). |
Max Discharge Current | 50A (0°C–45°C) | @Constant Current (CC) | Min discharge voltage: 2.7V/cell. |
Terminal Configuration | Red UL3135-12AWG (+), Black UL3135-12AWG (-) | Connector Type | For high-current applications. |
AC Impedance | ≤160mΩ | @1kHz | Measured with digital impedance analyzer. |
Weight | ~4.5kg | Including enclosure and connectors. | |
Dimensions | 195mm(L) × 185mm(W) × 80mm(H) | Excluding wiring harness. |
Cycle Life
Test Conditions | Cycle Count | Capacity Retention | Standard |
0.5C Charge + 0.5C Discharge | 300 cycles | ≥97% @100%DOD | IEC 61434-2015 (equivalent) |
Typical Discharge Profile:
Operating Temperature Range
Category | Range | Unit | Standard Compliance |
Charge Temperature | 0°C – 45°C | ℃ | GB/T 36276-2018 |
Discharge Temperature | -20°C – 60°C | ℃ | GB/T 36276-2018 |
Storage Temperature | -20°C – 45°C | ℃ | ≤1 month (50% SOC); ≤12 months (25°C SOC) |
Certifications
Key Features
BMS Specifications
Function | Setting | Threshold | Action |
Cell Overvoltage | Enable | 4.25V ±0.03 | Cut-off + recovery after <3 seconds. |
Cell Undervoltage | Enable | 2.7V ±0.1 | Cut-off + recovery after <1.5 seconds. |
Battery Overvoltage | Enable | 58.8V | Cut-off + recovery after <1.05 seconds. |
Battery Undervoltage | Enable | 2.7V | Cut-off + recovery after <5 seconds. |
Temperature Protection | Charge: 52°C / Discharge: 65°C | ±5°C Sampling Error | Cut-off + recovery when temp returns to threshold. |
Applications
Usage Warnings & Precautions
Storage Guidelines
Warranty & Disclaimer